2023-07-11 20:27:15, 陈江照 天美仪拓实验室设备(上海)有限公司
反式(p-i-n)钙钛矿太阳能电池具有与不同底电池兼容、可低温制备(≤100℃)、稳定性优异等优势。因此,反式电池的发展对于钙钛矿太阳能电池的商业化应用至关重要。近年来,反式电池引起了学术界和工业界广泛的关注,效率和稳定性取得了巨大的进展。然而,目前效率超过25%的反式电池仍然使用含MA+和Br-的钙钛矿吸光材料,常常使用MA+和Br-调节晶体生长和稳定α-FAPbI3的光活性黑色相。
然而,MA+在钙钛矿晶格中容易挥发和逸出,这会降低电池的光和热稳定性。此外,混合卤化物(I/Br)钙钛矿常常会发生相分离,这种现象会导致器件在光照和热老化下加速分解。空穴传输层/钙钛矿埋底界面常常存在大量的深能级陷阱态。埋底界面处的能量势垒导致界面空穴提取受阻,从而降低了器件的光伏性能。总之,界面非辐射复合进一步降低反式器件的光伏性能。
针对上述问题,重庆大学臧志刚和陈江照等人通过在无甲铵钙钛矿前驱液中引入少量的2-氨基茚满盐酸盐,在埋底界面原位形成了自下而上的2D/3D异质结,调控了钙钛矿结晶,钝化了3D钙钛矿晶界缺陷,优化了埋底界面能级排列,显著抑制了埋底界面非辐射复合损失。
基于反式电池实现了25.12%(认证效率为24.6%)的效率,这是反式无甲铵钙钛矿太阳能电池报道的最高效率。未封装电池最大功率点持续跟踪1500小时后仍能保持初始效率的98%。封装的电池在85℃/85%RH老化1200小时后保持初始PCE的92%。
Fig. 1┃Structural characterizations of the bottom-up 2D/3D heterojunction at buried interface. a, ToF-SIMS profile of ITO/NiOx/PTAA/Al2O3/perovskite with bottom-up 2D/3D perovskite heterojunction at buried interface (2D spacer species: CN- and Cl-, ammonium salt: CN-). b, 2D GIWAXS mappings of the control and target perovskite films with different incidence angles. c, PL spectra of the target perovskite film obtained from different incident directions. The perovskite films were deposited on ITO/NiOx/PTAA/Al2O3substrate. d, Cross-sectional HRTEM image of the target PSC. e, Device configuration of the inverted PSCs with bottom-up 2D/3D perovskite heterojunction at buried interface.
Fig. 2┃Charge carrier dynamics. a,b, TRPL spectra of the control and target perovskite films deposited on a bare glass substrate (a) and glass/NiOx/PTAA/Al2O3 substrate (b). TRPL measurements were conducted with excitation from the glass side and with an emission wavelength of 810 nm. c,d, Transient reflection (TR) spectroscopy measurements for the control (c) and target (d) perovskite films on NiOx/glass substrate. TRS measurements were performed with excitation from glass side.
Fig. 3┃Device performance and stability. a, PCE histogram of 20 PSCs with (target) and without (control) bottom-up 2D/3D heterojunction at buried interface. b, J-V curves obtained in forward and reverse scans of the champion target PSCs. The insets show the relevant photovoltaic parameters. c, Comparison of the photovoltaic performance of the inverted PSC in this work with literatures which reported PCEs over 23%. More details are shown in Table S4. d,J-V curve of the best performing target device with an area of 1 cm2. The insets show the relevant photovoltaic parameters. e, PCE of the unencapsulated control and target devices measured at maximum power point under continuous one-sun illumination at 55 ± 5 °C in N2 atmosphere. The initial PCE of control, target-1, and target-2 devices are 21.73%, 24.42%, and 24.11%, respectively. f, Damp-heat stability of the encapsulated control and target devices following the ISOS standards (85 ℃/85% RH). The initial PCE of control and target devices are 22.15±0.13% and 24.32±0.20%. The error bar is the standard deviation of three devices.
论文链接:
https://www.nature.com/articles/s41560-023-01295-8
光源推荐
HPL激光器
重庆大学臧志刚和陈江照等人通过在无甲铵钙钛矿前驱液中引入少量的2-氨基茚满盐酸盐,自下而上形成的2D/3D异质结,钝化3D钙钛矿晶界缺陷,优化了埋底界面能级排列,显著抑制了埋底界面非辐射复合损失。本研究利用爱丁堡FLS1000荧光光谱仪获取发光光谱,钙钛矿材料通常需要高功率脉冲激光器进行激发从而获取瞬态光谱信息,爱丁堡全新推出高功率皮秒脉冲激光器,拥有标准模式和高功率模式,重频可达到80MHz,欢迎各位老师垂询。
天美分析更多资讯
06-03 检测家
一地发布 检验检测「黄金十条」!通过全国重点实验室认定,最高资助1000万!06-03
实验室溶剂混溶表06-02
专家在线开讲 | 北京市食检院 林立主任:GB5009.8-2023标准修订情况介绍06-02
前方高能预警:来自00后的实验室警告06-01
专家在线开讲 | 任一平教授:GB 5009.296-2023 标准解读及应用06-01
激发创新活力-推进兴粮兴储|开元弘盛参加全国粮食和物资储备科技活动周06-01 开元弘盛
喜讯|科诺美抗癫痫药物检测系列产品获批医疗器械二类注册证05-31
科诺美助力水质检测解决方案05-31 科诺美Chromai
德米特TDM专文 靠谱! | 危重症患者如何开展β-内酰胺治疗药物监测?05-31
“创新点亮未来” - 钢研纳克参加2024年科学仪器开发者大会05-31 钢研纳克
解决方案|顶空/气相色谱-质谱法测定食用油中邻苯二甲酸酯05-31
实用干货 深化油类检测应用,推动行业高效发展05-31
活动回顾|东西分析亮相2024中国(郑州)润滑油、脂及汽车养护展览会05-31
科学仪器国潮星起!第二十一届中国国际科学仪器及实验室装备展览会在京开幕05-31
监测数据造假,如何分清各方责任?05-31
杜马斯法测定食品中氮/蛋白质含量的解决方案 | 德国元素Elementar05-31 德国元素
新品尝鲜|基毒分析难点揭秘,岛津“柱”您一臂之力05-31 市场部
特色方案|缬沙坦胶囊中13种亚硝胺杂质的测定05-31 市场部
特色方案|二甲双胍片中N,N-二甲基亚硝胺(NDMA)的测定05-31 市场部