光谱重复性 | <0.5cm-1 | 最低波数 | 250 cm-1 |
光谱范围 | 250-2700 cm-1 | 空间分辨率 | 横向1um,纵向1um |
光谱分辨率 | 6cm-1 | 仪器种类 | 便携/手持式拉曼光谱仪 |
生物科学是生命科学的基础,学生本科毕业后除在生物科学、生物技术和生态学等领域继续深造外,还可以在医学、农业学科领域继续深造。各高校应依据自身办学定位和人才培养目标,积极应对社会对多样化人才培养的需要,满足学生继续深造和不同的创业、就业志向。积极适应我国经济发展的新常态,树立先进的创新创业教育理念,创新办学机制,改革教学方式和内容,培养创新创业的生力军。
GENERALDESCRIPTION
ATR2110 portable Ramanspectrometer is suitable for field operation. The outstanding reliability makesthe detection result much accurate. The excellent low stray light conditionsthat enable the spectrometer has a wide range of application, especially in thebiochemical analyzer, food safety, pharmaceutical engineering. Themulti-function software facilitated the spectral analysis process inapplication. The remote experiment through internet access makes the bald testitem much easier.
FEATURES
linear CCD with TEC cooling;
low noise circuit;
Powerful embedded software;
Fluorescent background eliminate;
Peak searching and indicating;
10.1’’ LCD;
Android Operation System;
USB 2.0;
Touch screen and Keyboard input;
Friendly HMI;
Battery Endurance > 5 hours;
Remote control via LAN;
IP67 case;
APPLICATIONS
Biological science
Pharmaceuticalengineering
Forensic analysis
Agriculture and food safety
Gemstone
Environmentalscience
ATR2110 System |
|
Interface | USB 2.0/LAN |
Spectral region | 250-2700 cm-1 |
Spectral resolution | 6cm-1 (按美国国标方法测定) |
Signal-to-Noise | >400:1 (918 cm-1 of Acetonitrile,10s accumulation, 200mW) |
Exciting Laser |
|
Center Wavelength | 785nm (+/-1nm) |
FWHM | 0.1 nm |
Output power | ≥450 mW |
High Reliability Figure 3.1 and Figure 3.2 showed thetemperature reliability testing results of fives ATR2110 portable Ramanspectrometers. The testing temperature range was from 5 oC to 40 oC.The spectrometer was kept more than 1 hour at every temperature spots.Acetonitrile was used as the standard sample in the testing. The testingresults were calculated using 918 cm-1 of acetonitrile. Thewavenumber shift was 1 cm-1 or less(as show in Fig. 3.1). The peakintensity variation was less than 10% (as show in Fig. 4).
Temperature range: 5-40 centigradeWavenumber shift: < 1 cm-1 |
Fig. 3.1 Wavenumber shift results testing from 5 oC to 40oC of fives ATR2110 portable Raman spectrometers
Temperature range: 5-40 centigrade
Spectral intensity variation: < 10%
Fig.3.2 Intensity variation testing from 5 oC to 40 oC offives ATR2110 portable Raman spectrometers
4 订购信息型号波长(nm)功率(mW)波数范围cm-1ATR2110-473473100150-4000ATR2110-532532100150-4000ATR2110-785-27785600250-2700ATR2110-785-40150-4000ATR2110-830830600150-4000ATR2110-10641064600150-4000其他波长可定制 |
奥谱天成 ATR2110 便携式拉曼光谱仪 用于生物科学,ATR2110
奥谱天成 ATR2110 便携式拉曼光谱仪 用于生物科学信息由奥谱天成(厦门)光电有限公司为您提供,如您想了解更多关于奥谱天成 ATR2110 便携式拉曼光谱仪 用于生物科学报价、型号、参数等信息,欢迎来电或留言咨询。