Dynatrol® CL-10RH Liquid Level Switch The Dynatrol® Type CL-10RH Liquid Level Detector and EC-102B or EC-103C
Control Unit is used for high, intermediate or low point level detection
of liquids and slurries. This is typically a replacement unit for
existing CL-10RH units in the field. The CL-10GH is phasing out the
older style liquid level detector. Information The CL-10RH Liquid Level Switch is being phased out and replaced by the newer CL-10GH type level detector.
CL-10RH Specifications
• Explosion Proof: CSA NRTL/C approved for Class 1, Group D, Division 1 Class 2, Groups E, F, and G
• Pressure Rating: 3000 PSIG @ 100°F
• Temperature Rating: 300°F (High Temperature Construction Available)
• Pressure Connection: ¾-inch NPT
• Conduit Connection: ½-inch NPT
• Process Contact Surfaces: 316 S.S. (standard)
EC-102B Control Unit
• Explosion Proof: CSA NRTL/C approved for Class 1, Group D, Division 1, Class 2, Groups E, F, and G
• Voltage Supply (Nominal):120 volts, 60Hz
• Temperature Rating: 125°F Maximum
• Power Consumption: 5 VA
• Conduit Connections: ½-inch
• Contacts: SPDT 2A @ 120 VAC (Non-Inductive)
Principle of Operation The Dynatrol® liquid level paddle is driven into vibration by a driver
coil. A second coil produces a voltage proportional to a 0-3/4-inch
range of level. As the process covers the paddle, the output responds
proportionally by transmitting a 1-5mA or 4-20mA signal.