    使用 390-LC 多检测器套件 (MDS) 与通用校准对聚N-异丙基丙烯酰胺智能材料进行 GPC 分析

    发布时间: 2016-07-22 10:34 来源: 安捷伦科技(中国)有限公司
    领域: 临床生物化学/分子生物学,其他
    样品:聚N-异丙基丙烯酰胺智能材料项目:通用校准对聚N-异丙基丙烯酰胺智能材料进行 GPC 分析
    参考:-

    方案文件名 下载

    使用 390-LC 多检测器套件 (MDS) 与通用校准对聚N-异丙基丙烯酰胺智能材料进行 GPC 分析

    下载此篇方案

    “Smart materials” are capable of varying their physical properties in response to environmental changes or stimuli. Such stimuli include temperature, pH, solvent composition, and electric field strength. In particular, smart hydrogels, which change their shrinking and swelling characteristics in response to external stimuli, have been studied for use in engineering and biomedical applications, such as controlled drug release. Poly(n-isopropylacrylamide) (PNIPAM) gel is an important smart hydrogel that responds to temperature changes. PNIPAM gels exhibit negative thermosensitivity, meaning that they undergo a significant level of shrinkage with increasing temperature. Precise control over a hydrogel’s shrinking and swelling characteristics is desirable since this may lead to control over its drug release/ uptake properties. Among other important properties that affect the thermosensitivity of PNIPAM, such as particle structure and size, a key characteristic is the molecular weight distribution. The molecular weight distributions of two PNIPAM polymers were accurately measured by means of GPC with online viscometry, allowing application of the universal calibration technique. This method permits an accurate calibration of the GPC system based upon molecular size in solution (using the relationship between the viscosity of the eluting polymer and its molecular weight). This in turn allows accurate molecular weights to be calculated even though the polymer standards used are not chemically identical to the polymer under investigation, as the column is separating on size not molecular weight. As a result, the molecular weight data usually obtained via this technique are very accurate, in contrast to conventional GPC employing a concentration detector only (eg UV, RI), which provides molecular weight data relative to the polymer calibration standards used. The 390-MDS can be used to provide accurate molecular weights for polymers of unusual structure by employing differential refractive index and viscometry detectors in combination.

    扫描下方二维码,关注“安捷伦视界”微信公众号,获取更多解决方案资讯。

    扫描下方二维码,关注“安捷伦视界”微信公众号,获取更多解决方案资讯。
    移动版: 资讯 直播 仪器谱

    Copyright ©2007-2024 ANTPEDIA, All Rights Reserved

    京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号