工商注册信息已核实!参考报价: | 面议 | 型号: | Laserino |
品牌: | SpotOptics | 产地: | 美国 |
关注度: | 19 | 信息完整度: | |
样本: | 典型用户: | 暂无 | |
供应商性质 | 区域代理 | 产地类别 | 进口 |
400-6699-117转1000
业界首台基于波前探测技术的,全面同时测量激光光束laser beams、光斑分布beam-profiling 的二合一激光测试设备。全面评价激光品质:基于波前分析的激光失常测试Aberrations obtained from the wavefront sensorM² 测试,通过光斑光强分布得到measurement of the beam-quality using the beam-profiler激光束腰,位置、发散角Measurement of beam-waist, position of beam-waist and divergence angle高斯形貌Fit of Gaussian profile to image在线调整激光,对焦、对准Real-time adjustment of laser (up to a speed of 900 Hz using a sub-window)对激光元件,透镜、镜片测试Measure the optical quality of lenses, mirrors etc 有两种型号以适合不同波长使用 0.4 μ to 1.1 μ and NIR 0.9 μ to 1.7 μ Laserino-Pro-VisWavefront sensor with fixed collimator that can be used in external illumination mode in white-light or laserTwo uncooled cameras allow the complete control of laser beam: the first camera is used for wavefront analysis , the second camera for imaging beam-profile of laserFront flange allows easy mounting and dismounting of lenses and collimatorsStandard sampling: 30 x 30 spotsFor testing lasers from 0.4 μ to 1.1 μΦ max=6.7mm (without beam-expander)Φ max=58.0mm (with BE60) Laserino-ProIRWavefront sensor that can be used in external illumination mode with laserOne uncooled Lead oxysulfide Vidicon camera can be switched from wavefront analysis to beam-profiler to get a complete picture of the laser beamFront flange allows easy mounting and dismounting of lenses and collimatorsMaximum sampling: 20 x 20 spotsFor testing lasers from 0.4 μ to 1.8 μ; optimized in the wavelength range:0.7 μ to 1.8 μΦ max = 8.0 mm (without beam-expander)Φ max = 58.0 mm (with BE60) Sensoft: The wavefront sensor based instrument comes with Sensoft Laserino, the Shack-Hartmann wavefront sensor control and analysis software optimized for laser. The package is available under any Windows operating system (2000/XP).All the features of Optino-EE30Laser beam 3D and contour profile in real-timeFit of Gaussian profile to imageBest focus determination based on analysis of beam diameterReal-time adjustment of laser (up to a speed of 900Hz using a sub window)M² measurement of the beam-quality using the beam-profilerMeasurement of beam-waist, position of beam-waist and divergence angle |
Laserino 激光波前测试技术指标 |
Feature SpecificationType of element that can be tested Lasers from 0.4 μ to 1.1 μ with Laserino-ProVis wavefront sensorLasers from 0.9 μ to 1.7 μ with Laserino-ProNIR wavefront sensorOptical elements with external illuminationDiameter of optical element that can be tested(1) Practically any diameterDiameter of lenslets(2) 0.2 mmFocal length of lenslets(3) 22 mm for Laserino-ProVis wavefront sensor, 11 mm for Laserino-ProNIR wavefront sensorStandard sampling on the pupil(4) 30 x 30 spotsMaximum sampling(5) 100 x 100 spots with large format cameraAnalysis Software SensoftRepeatability of measurement of Zernike polynomials(6) < λ/300 rmsRms repeatability of wavefront measurement(7) < λ/200 rmsAbsolute precision(8) Depends on the surface quality of the reference optical element. Typically λ/20 - λ/100Wavelength range (visible camera)(9) 0.375 μ - 1.1 μ with standard cameraWavelength range (IR camera)(10) 0.9 μ - 1.7μTilt measurement accuracy (angle depends on the size of the optical elements) 4 μ radDimensions 9 (H) x 22 (L) x 9 (W) cm.Power requirement (Vis Fiber optic light source) 120V or 220VPower requirement (stepper motor) 12 V, 500 ma.Height of optical axis from base 65.5 mm Notes and explanations for the specifications table:(1) With the appropriate auxiliary optics, optical elements of almost any diameter can be tested(2) Lenslets with different diameters available on request (3) Lenslets with different focal lengths available on request (4) With the standard CMOS camera (chip size 6.8 x 8.6 mm²). Pixel size: 6.7μ(5) Depends on the chip size of the camera. In Optino wavefront sensor, the camera is mounted externally, and can be changed easily. For details, see separate section (6) Repeatability of measurement obtained by combining 100 SH images taken in succession. The error of this coefficient depends on the sampling used for obtaining the SH image(7) Repeatability of measurement obtained by combining 100 SH images taken in succession (8) This will determine the final accuracy of the measurements, as the SH test is a differential test (9) Other cameras with an extended range can be used (10) Other cameras with an extended range can be used |
激光光斑、光束分析技术指标 |
Feature Specification Type of element that can be measured Lasers from 0.4 µ to 1.1 µ with Laserino-ProVis wavefront sensorLasers from 0.9 µ to 1.7 µ with Laserino-ProNIR wavefront sensor Resolution of imaging lens motor 21 µ per step Accuracy of determination of beam waist diameter ± 2 % Accuracy of determination of beam waist location ± 8 % of beam Rayleigh distance Accuracy of determination of M2 : Beam quality ± 5 % Accuracy of determination of divergence angle ± 5 % Divergence range measurement 632 nm 0.5 mrad to 20.0 mrad (with beam-expander) Divergence range measurement 1550 nm 1.2 mrad to 50.0 mrad (with beam-expander) Max Beam diameter 23 mm Clip levels User selected (continuously variable) Diameter computation Gaussian or second moment |
激光产品 信息由光傲科技股份有限公司为您提供,如您想了解更多关于激光产品 报价、型号、参数等信息,欢迎来电或留言咨询。
注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途