您好,欢迎您查看分析测试百科网,请问有什么帮助您的?

稍后再说 立即咨询
奥谱天成(厦门)光电有限公司
400-6699-117转1000
热门搜索:
分析测试百科网 > 奥谱天成 > 便携式 > 奥谱天成_ATR2110_便携式拉曼光谱仪

奥谱天成_ATR2110_便携式拉曼光谱仪

参考报价: ¥98000 RMB(人民币) 型号: ATR2110
品牌: 奥谱天成 产地: 福建
关注度: 722 信息完整度:
样本: 典型用户: 暂无
价格范围¥5万-10万应用场景便携台式
光谱重复性<0.5cm-1最低波数250 cm-1
光谱范围250-2700 cm-1空间分辨率 横向1um,纵向1um
光谱分辨率 6cm-1仪器种类便携/手持式拉曼光谱仪
咨询留言 在线咨询

400-6699-1171000

AI问答
可以做哪些实验,检测什么? 可以用哪些耗材和试剂?

GENERALDESCRIPTION

ATR2110 portable Ramanspectrometer is suitable for field operation. The outstanding reliability makesthe detection result much accurate. The excellent low stray light conditionsthat enable the spectrometer has a wide range of application, especially in thebiochemical analyzer, food safety, pharmaceutical engineering. Themulti-function software facilitated the spectral analysis process inapplication. The remote experiment through internet access makes the bald testitem much easier.

FEATURES

  • linear CCD with TEC cooling;

  • low noise circuit;

  • Powerful embedded software;

  • Fluorescent background eliminate;

  • Peak searching and indicating;

  • 10.1’’ LCD;

  • Android Operation System;

  • USB 2.0;

  • Touch screen  and Keyboard input;

  • Friendly HMI;

  • Battery Endurance > 5 hours;

  • Remote control via LAN;

  • IP67 case;


    APPLICATIONS

  • Biological science

  • Pharmaceuticalengineering

  • Forensic analysis

  • Agriculture and food safety

  • Gemstone

  • Environmentalscience

ATR2110 System


Interface

USB 2.0/LAN

Spectral region

250-2700 cm-1

Spectral resolution

6cm-1  (按美国国标方法测定)

Signal-to-Noise

>400:1 (918 cm-1 of Acetonitrile,10s accumulation, 200mW)

Exciting Laser


Center Wavelength

785nm (+/-1nm)

FWHM

0.1 nm

Output power

≥450 mW


High Reliability

  Figure 3.1 and Figure 3.2 showed thetemperature reliability testing results of fives ATR2110 portable Ramanspectrometers. The testing temperature range was from 5 oC to 40 oC.The spectrometer was kept more than 1 hour at every temperature spots.Acetonitrile was used as the standard sample in the testing. The testingresults were calculated using 918 cm-1 of acetonitrile. Thewavenumber shift was 1 cm-1 or less(as show in Fig. 3.1). The peakintensity variation was less than 10% (as show in Fig. 4).


Temperature range: 5-40 centigradeWavenumber shift: < 1 cm-1

Fig. 3.1 Wavenumber shift results testing from 5 oC to 40oC of fives ATR2110 portable Raman spectrometers

 

Temperature range: 5-40 centigrade

Spectral intensity variation: < 10%

Fig.3.2 Intensity variation testing from 5 oC to 40 oC offives ATR2110 portable Raman spectrometers

4 订购信息

型号波长(nm)功率(mW)波数范围cm-1ATR2110-473473100150-4000ATR2110-532532100150-4000ATR2110-785-27785600250-2700ATR2110-785-40150-4000ATR2110-830830600150-4000ATR2110-10641064600150-4000其他波长可定制


奥谱天成_ATR2110_便携式拉曼光谱仪信息由奥谱天成(厦门)光电有限公司为您提供,如您想了解更多关于奥谱天成_ATR2110_便携式拉曼光谱仪报价、型号、参数等信息,欢迎来电或留言咨询。

注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途

移动版: 资讯 直播 仪器谱

Copyright ©2007-2024 ANTPEDIA, All Rights Reserved

京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号