技术参数:
PSD/3 Specifications:

Power Supply:

Voltage: 24 VDC (±5%)

Current: 1 amp typical; 2 amp peak

Syringes:

Syringe Type: For 4.5 in module, Hamilton GASTIGHT® Half Height Instrument Syringes

Sizes: 12.5 uL, 25 uL, 50 uL, 125 uL, 250 uL, 500 uL, 1.25 mL, 2.5 mL, 5 mL, 12.5 mL

Fluid Contact: Glass, PTFE, CTFE

Syringe Drive:

Drive Type: Closed loop DC Servo Motor: self lubricating and wear compensating lead nut/screw (no lubrication)

Travel/speed: 30mm: 0.5seconds to 60 minutes for full stroke. Dependent upon system configuration.

Resolution: 30,000 increments full stroke on 30 mm stroke length

Adjustable to the following counts:
Standard/half 1,000 counts
Standard/full 2,000 counts
High/half 15,000 counts
High/full 30,000 counts


Inaccuracy: ±1.0% @ > 30% stroke; ±1.2% @ 5% stroke (syringe dependent)

Imprecision +0.2% @ > 30% stroke; ±0.5% @ 5% stroke (syringe dependent)

Valves:

Valve Type: Hamilton HV plug valves; snap-in/out

Port Size: .039" (1.0 mm), .059" (1.5 mm), or .070" (1.8mm)

Positions: 2 position @ 90° typical; multiple position possible (15° increments)

Fluid Contact: PTFE & CTFE

Fittings: Hamilton 1/4" - 28 male tube fittings with flared FEP or PTFE tubing

Valve Drive:

Drive Type: Closed loop DC motor with encoder

Speed: 390 ms @ 90°

Environment

Operating Temperature: 60°F to 95°F (15°C to 35°C)

Operating Humidity: 20% to 90%, non-condensing

Storage Temperature: -5°F to 158°F (-20°C to 70°C)

Storage Humidity: 20% to 95%, non-condensing

Communication

Protocol: Hamilton Reno Protocol 1 or Hamilton Bonaduz DIN Protocol

Interface: RS-232C

Baud Rate: 9600

Daisy Chain: 16 modules

Software Features:

Memory Storage: FLASH

Stored Methods: 1

TTL I/O: 1

Auxiliary Input: 1 (e.g. hand probe)

Step/Prime Modes: Yes

Firmware Revision: Programmable FLASH (In-System)

Syringe Program Variables: Position, Speed, Prime Speed (system default), Backlash Compensation (return steps), & On The Fly Speed Change

Syringe Program Variables: Delays Overload/Zero Sensitivity TBD through testing

Valve Program Variables: Position and Speed



PSD/3 Dimensions: Click here for a larger image.

Hamilton 注射泵(PSD/3)信息由北京康林科技有限责任公司为您提供,如您想了解更多关于Hamilton 注射泵(PSD/3)报价、型号、参数等信息,欢迎来电或留言咨询。

注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途

Hamilton 注射泵(PSD/3) - 产品推荐

移动版: 资讯 直播 仪器谱

Copyright ©2007-2023 ANTPEDIA, All Rights Reserved

京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号