您好,欢迎您查看分析测试百科网,请问有什么帮助您的?

稍后再说 立即咨询
北京欧兰科技发展有限公司
400-6699-117转1000
热门搜索:
分析测试百科网 > MCL > TIRF Module > 全内反射荧光显微镜(TIRF)模块

全内反射荧光显微镜(TIRF)模块

参考报价: 面议 型号: TIRF Module
品牌: MCL 产地: 暂无
关注度: 1164 信息完整度:
样本: 典型用户: 暂无
产品类型倒置荧光显微镜仪器结构落射式荧光显微镜
价格范围100万-150万激发光源高压汞灯
咨询留言 在线咨询

400-6699-1171000

AI问答
可以做哪些实验,检测什么? 可以用哪些耗材和试剂?


Features
  • Easy to switch from epi-illumination to TIR illumination or any angle in between (HILO)

  • Easy to install

  • Easy to align with tip/tilt adjustment of fixed mirror, translatable mirror, and translatable lens

  • Compatible with RM21™ and MicroMirror TIRF


Product Description

Mad City Labs offers a module that converts the RM21™ platform into a total internal reflection fluorescence (TIRF) microscope. The TIRF module makes the transition between epifluorescence, TIRF, and HILO (Highly Inclined and Laminated Optical) microscopy techniques effortless. The TIRF module is a precision aligned add-on component to the RM21™. The TIRF module controls the angle of illumination and the focusing of the excitation beam onto the back focal plane of the objective lens.

The TIRF module enables straightforward adjustment of the excitation beam from along the optical axis for standard epi-illumination of the sample to TIR illumination of the sample, and any angle in between. The figures below illustrate the use of the TIRF module in epi-illumination and TIR illumination.

The excitation beam is reflected from M1, which is attached to a kinematic mount for fine direction control. M1 is fixed and does not translate.  The excitation beam reflects from M2, which can be translated along the beam path using a micrometer.  M2 is also attached to a kinematic mount for fine control of the beam.  L1 focuses the excitation beam onto the back focal plane of the objective lens.  L1 can be adjusted by the kinematic mount and translated axially using a micrometer. The beam translation (shown in the Detailed view of TIRF Module, above) moves the location of the beam on the back focal plane of the objective for epi-illumination/TIR/HILO.


M3 is the TIRF module's exit mirror and is used to direct the TIR exit beam to the TIRF Lock™ module. TIRF Lock™ keeps the sample in the focal plane by maintaining a constant TIRF signal. TIRF Lock™ measures the displacement of the exiting TIR beam and is used with a Z axis sample nanopositioner to keep the sample in focus.

The TIRF module is capable of controlling the full range of sample illumination angles from EPI to TIR.  In practice, the sample illumination angle is adjusted for each experiment to provide the optimized signal-to-noise (SNR) for the available fluorescent signal.  In some experiments, optimal SNR is achieved using HILO illumination, which brings the excitation light in at an angle very close to the critical angle.  The excitation beam thus enters the sample by refraction, but does so at a sharp angle and can achieve better SNR by limiting the excitation of out of focus probes. HILO is one specialized example of the techniques that can be done using the TIRF module for RM21™.



Related Products

 

全内反射荧光显微镜(TIRF)模块信息由北京欧兰科技发展有限公司为您提供,如您想了解更多关于全内反射荧光显微镜(TIRF)模块报价、型号、参数等信息,欢迎来电或留言咨询。

注:该产品未在中华人民共和国食品药品监督管理部门申请医疗器械注册和备案,不可用于临床诊断或治疗等相关用途

全内反射荧光显微镜(TIRF)模块 - 产品推荐
全内反射荧光显微镜(TIRF)模块 - 相关产品
移动版: 资讯 直播 仪器谱

Copyright ©2007-2024 ANTPEDIA, All Rights Reserved

京ICP备07018254号 京公网安备1101085018 电信与信息服务业务经营许可证:京ICP证110310号